Review of 62 Covid-19 imaging AI models published in 2020 found none fit for clinical use
January 1, 2020.
A review led by University of Cambridge researchers examined machine learning models published in 2020 to detect or predict Covid-19 from chest X-rays and CT scans. Of 2,212 studies identified, 62 passed quality screening, and the authors judged none to be of potential clinical use because of methodological flaws or biases. Several used children's X-rays as non-Covid examples, so models could learn to tell children from adults. The review appeared in Nature Machine Intelligence in 2021.
Summarized in our own words from the sources below and checked against them. Not yet written up to our full standard.
Provenance
Where each fact comes from.
This is a checked entry
We read the reports listed here, checked the date, the place and who was involved against them on November 20, 2026, and summarized them in our own words. It has not yet been written up to our full standard, which adds a sourced account of what happened, what is confirmed and what is not. How the standards differ. Have a better source? Send it to us.Sources
- News report
Nature, March 15, 2021. Common pitfalls and recommendations for using machine learning to detect and prognosticate for COVID-19 using chest radiographs and CT scans. Read - News report
STAT, June 2, 2021. Machine learning is booming in medicine. It's also facing a credibility crisis. Read - News report
University of Cambridge, March 15, 2021. Machine learning models for diagnosing COVID-19 are not yet suitable for clinical use. Read - Incident index
AI Incident Database, January 1, 2020. AIID incident #535. Read
Checked Nov 20, 2026. First logged Nov 19, 2026.
Status history
Changes to this exhibit's status, with the date and what changed it.
- Nov 20, 2026Checked against the University of Cambridge and Nature Machine Intelligence and summarized in our own words.University of Cambridge; Nature
- Nov 19, 2026Imported from the AI Incident Database (incident 535) with the reports it lists.AI Incident Database
Take it with you
Share the cover
Cite this exhibit
AI Incident Tracker. (2026, November 19). Review of 62 Covid-19 imaging AI models published in 2020 found none fit for clinical use (AIT-0682). https://aiincidenttracker.com/AIT-0682
Up next
More like this
See the room- Jul 3, 2023Study found text-to-image models depicted trans and nonbinary people as more stereotyped and sexualisedBias and discrimination
- Dec 2021Justice Department found its PATTERN prisoner risk tool overpredicted reoffending for Black, Hispanic and Asian peopleBias and discrimination
- Oct 24, 2019Study found a hospital risk algorithm sold by Optum rated Black patients as healthier than equally sick white patientsBias and discrimination
- 2014Stanford-led study found the IRS audited Black taxpayers about three to five times as often as other taxpayersBias and discrimination